Skip to main content Skip to footer

FAQ

The most frequently asked questions about the use of radiello®

Produced in the laboratories of the Maugeri Environmental Research Centre, radiello® is an air quality monitor that is effective, silent and easy to use. Thanks to its very small size, it can be attached to clothes or hung on any type of support.

Air pollution monitoring allows to determine the concentration of airborne compounds, as gases or as vapours.

  • Volatile Organic Compounds (VOCs)
  • Aldehydes
  • Phenols
  • 1,3-butadiene and isoprene
  • Acetic acid and formic acid
  • Hydrogen sulphide (H2S)
  • Hydrochloric acid (HCl)
  • Hydrofluoric acid (HF)
  • Ammonia (NH3)
  • Ozone (O3)
  • Nitrogen dioxide and sulphur dioxide (NO2, SO2)
  • Anaesthetic gases

Our experts are always on hand to provide you with personalised feedback. Fill in the form on this page.

radiello® is designed for indoor and outdoor air monitoring: industrial sites and offices, residential sites such as homes and schools, urban public places and remote locations.

The components required to carry out sampling consist of:

  • supporting plate
  • diffusive body
  • adsorbing cartridge
  • barcode label for sample identification

Most radiello® cartridges can only be purchased in packs of 5 or 20.

The following cartridges are also available individually as “starter kit” (with one additional cartridge supplied as a blank) and include a supporting plate with clip, vertical adapter, diffusive body and barcode label:

  • Code RAD130S: BTEX/VOCs, desorption with CS2
  • Code RAD141S: 1,3-butadiene and isoprene, thermal desorption
  • Code RAD145S: BTEX/VOCs, thermal desorption
  • Code RAD170S: H2S

Adsorbing cartridges for thermal desorption (code 145 for VOCs, code 141 for 1,3-butadiene and isoprene, code 147 for phenol, methyl- and dimethylphenols) can be reconditioned after laboratory analysis and can typically be reused at least 20 times. The other adsorbing or chemiadsorbing cartridges can only be used once.

The diffusive bodies can be reused several times until they are visibly dirty or damaged, after which replacement is recommended. The number of sampling cycles they can be subjected to depends largely on the characteristics of the environment they are exposed to, in particular the level of fine particulate matter.

All other radiello® components can be reused many times, until they are visibly dirty or damaged. It is recommended to wash the supporting plates between uses if using impregnated cartridges (e.g. code 166). This avoids cross-contamination due to any adsorbing solution residue present in the threaded cavity.

Yes. The expiry date is shown on the packaging together with the production batch code. It is recommended to store the cartridges in their packaging, respecting the specified storage methods and times.

The cartridge sleeve shows the standard expiry date, valid for storage in the refrigerator at 4°C (6 months from the date of production). The extended expiry date, valid only when stored in a freezer at -18°C, is also shown on the box label.

The storage period before analysis corresponds to the product’s “shelf life” (see UNI EN 13528-2 or ISO 23320). After exposure, the relevant term is the “sample storage time”. Both periods must be respected, independently of one another.

Yes. radiello® does not present an ignition risk in explosive or flammable atmospheres.

The expiry date and batch number are shown on all individual plastic pouches containing the radiello® cartridges. If the outer packaging is damaged, the batch number can be used to find out the expiry date. In this case, contact our customer service.

The cartridges must be stored as specified on the label on the outside of the box (e.g. refrigerated, frozen and/or protected from light) or in the accompanying leaflet.

The Environmental Research Centre’s laboratories have extensive expertise in the analysis of radiello® cartridges. To request a quote, contact us on +39 049 806 4511 or complete the form here.

If the diffusive bodies become dirty (particularly after outdoor exposure), they can be soaked in a beaker containing water and a mild detergent. The beaker should be placed in an ultrasonic bath for 20 minutes.

Since diffusive bodies tend to float, a second smaller beaker can be placed inside the main one with enough water to submerge it a few centimetres. This keeps the diffusive bodies at the bottom of the beaker.

The diffusive bodies should then be rinsed with plenty of running water, then with laboratory water (grade I) and allowed to air dry.

If impregnated cartridges are used, it is recommended to wash the supporting plates between uses. This avoids cross-contamination due to any adsorbing solution residue.

Ready-to-use radiello® samplers, available for the main substances monitored using radiello®, are pre-assembled “ready-to-use” samplers with an adsorbing cartridge already inserted in the diffusive body closed with a screw cap, all in a sealed plastic container.

Ready-to-use radiello® samplers can be used very quickly and easily, and do not require specific technical skills.

How are they used? Apply the white adapter to a supporting plate (purchased separately), remove the pre-assembled radiello® sampler and click it into place on the plate.

The ready-to-use radiello® sampler begins to sample the moment it is removed from the sealed packaging.