Measuring the concentration in air of Volatile Organic Compounds or VOCs (aliphatic, aromatic, chlorinated hydrocarbons, alcohols, ethers, esters, ketones, etc.) can be carried out with two types of radiello® radial symmetry diffusive samplers:
- The radiello® VOC sampler with solvent desorption contains the RAD130 adsorbing cartridge. The cartridge consists of a stainless steel mesh cylinder (100 mesh), 60 mm long and 5.8 mm in diameter, filled with 530 ± 30 mg of 35–50 mesh activated carbon. The cartridge is inserted into the white diffusive body (RAD120). VOCs are captured by adsorption onto the activated carbon substrate, are desorbed using a suitable solvent (generally carbon sulphide) and analysed by capillary gas chromatography with flame ionisation detection or mass spectrometric detection (HRGC-FID or HRGC-MS). Thanks to the large adsorption capacity of the RAD130 cartridge, the solvent desorption sampler is recommended for workplace air sampling, even with high concentrations of VOCs, for one full or partial work shift. Sampling periods can continue for up to two weeks in urban or indoor air.
- The radiello® VOC sampler with thermal desorption contains the RAD145 adsorbing cartridge. The cartridge consists of a fine stainless steel mesh cylinder (3×8 µm openings), 60 mm long and 4.8 mm diameter, filled with 350 ± 10 mg of 35–50 mesh graphitised carbon (Carbograph 4). The cartridge is inserted into the yellow diffusive body (RAD120-2). VOCs are captured by adsorption onto the Carbograph 4 substrate, thermally desorbed and analysed by HRGC-FID or HRGC-MS. Thanks to the analytical sensitivity offered by this technique, the thermal desorption sampler is recommended for low concentration VOC sampling in ambient air or indoor air, for sampling periods of up to two weeks and for low concentration VOC sampling in workplace environments (including non-industrial) or for the monitoring of carcinogens for which a very low Limit of Detection (LOD) is required.
Using both techniques, the following classes of compounds can be sampled:
- aliphatic hydrocarbons (from n-hexane and its isomers to n-dodecane and its isomers)
- aromatic hydrocarbons (benzene, toluene, ethylbenzene, xylenes or BTEX, trimethylbenzene and its isomers, cumene, styrene and naphthalene)
- chlorinated hydrocarbons (trichloroethylene, tetrachloroethylene, 1,4-dichlorobenzene and 1,1,1-trichloroethane)
- esters (isopropyl acetate, n-butyl acetate, isobutyl acetate, etc.)
- glycol ethers and their esters (1-methoxy-2-propanol, 1-methoxy-2-propyl acetate, etc.)
- terpenes (α-pinene, d-limonene)